Standard Details and Drawings by Section

Jump to a Section


Accessible Ramps

Section Name Name
AR‐2.0 Curb Ramp Elements Definitions and Stand
AR‐3.0 Curb Ramp General Details
AR‐3.1 Detectable Warning Specifications
AR‐3.2A Detectable Warning Standard Layout
AR‐3.2B Detectable Warning Standard Layout
AR‐4.1 Dual Parallel Curb Ramps
AR‐4.3 Dual Perpendicular Curb Ramps with Attached Sidewalk
AR‐4.4 Single Perpendicular Ramp
AR‐4.5 Dual Flared Perpendicular Curb Ramps with Detached Sidewalk
AR‐4.6 Dual Perpendicular Curb Ramps with Detached Sidewalk
AR‐4.7 Sidewalk Driveway Detail
AR‐4.8 Detached Sidewalk Driveway Details

Back to top


Drafting

Section Name Name
D‐1 Approval Blocks
D‐2 Drafting Standards
D‐3 Standard Map Associated with Legal Description for 8‐1/2 x 11” Sheet

Back to top


Grading

Section Name Name
G‐1 Exterior Perimeter Property Line Grading for Fill Areas
G‐2 Grading for Interior Property Lines and Perimeter Property Lines in Cut Areas
G‐3 Wood Retaining Wall Details for Interior Property Lines
G‐4 Masonry/Concrete Retaining Way Detail for Fill Areas at Boundary and Project Phase Lines

Back to top


Landscaping

Section Name Name
L‐1 Tree Planting
L‐2 Shrub Planting
L‐3 Remote Control Valve
L‐4 Drip Irrigation Valve Assembly
L‐5 Quick Coupling Valve
L‐6 Master Valve Flow Sensor
L‐7 Flush Valve
L‐8 Air Relief Valve
L‐9 Pop‐Up Rotor Sprinkler
L‐10 Pop‐Up Spray Sprinkler
L‐11 Bubbler Sprinkler Head
L‐12 Drip Irrigation Multi‐Outlet Emitter
L‐13 Subsurface In‐Line Drip Irrigation Layout
L‐14 Subsurface In‐Line Drip Irrigation Center‐Feed Supply Manifold
L‐15 Subsurface In‐Line Drip Irrigation End‐Feed Supply Manifold
L‐16 Deep Watering Pipe for Trees
L‐17 Irrigation Controller Enclosure
L‐18 Irrigation System Trenching
L‐19 Drinking Fountain
L‐20 Post and Cable Fencing
L‐21 Post and Cable Fencing
L‐22 Removable Bollard
L‐23 Concrete Walk (In park Areas, not Frontage Areas)
L‐24 Concrete Mow Strip
L‐25 Bike Trail Paving Section
L‐26 Roadway Median Section
L‐27 Redwood Headerboard
L‐28 Double Pipe Gate
L‐29 Single Pipe Gate

Back to top


Storm Drainage

Section Name Name
SD‐1 10‐Year Peak Flow Sacramento Method Rainfall Zone 2, less than 80 Acres
SD‐1A Design Runoff Nolte Method Drainage Areas, less than 50 Acres
SD‐1B Design Runoff Nolte Method Residential Areas, 50‐160 Acres
SD‐1C Design Runoff Nolte Method Commercial Areas, 50‐160 Acres
SD‐2 10‐Year Peak Flow Sacramento Method Rainfall Zone 2, 80‐640 Acres
SD‐3 100‐Year Peak Flow Sacramento Method Rainfall Zone 2, less than 80 Acres
SD‐4 100-Year Peak Flow Sacramento Method Rainfall Zone 2, 80-640 Acres
SD‐5 Loss in Junction Due to Change in Direction of Flow in Lateral
SD‐6.0 Storm Drain Trench Detail
SD‐6.1 Storm Drain Pipe Bedding and Initial Backfill
SD‐6.2 Trench Dam Detail
SD‐7 Standard Precast Concrete Drainage Manhole
SD‐8A Type A Saddle Manhole
SD‐8B Type B Saddle Manhole
SD‐9 Grey Cast Iron Standard 24” Manhole Frame and Cover
SD‐10.1 Grey Cast Iron Standard 36” Manhole Frame and Cover (Page 1 of 2)
SD‐10.2 Grey Cast Iron Standard 36” Manhole Frame and Cover (Page 2 of 2)
SD‐11 Grate Type Manhole Cover
SD‐12.1 Drop Inlet Type B at Detached Sidewalk
SD‐12 Drop Inlet Type B
SD‐13 Drop Inlet Type C
SD‐14 Welded Steel Grate Frame
SD‐15 Welded Steel Grate
SD‐16 Center Support Assembly for Multiple Grates
SD‐17 Catch Basin Face Plate Assembly and Protection Bar
SD‐18 Drop Inlet Type F
SD‐19.1 Drop Inlet Type G, Type 2 CandG Only (Page 1 of 2)
SD‐19.2 Drop Inlet Type G, Type 2 C&G Only (Sheet 2 of 2)
SD‐19.3 Modified Type J Inlet
SD‐20 Drainage Inlet Type H
SD‐21.1 Corrugated Metal Pipe Drainage Inlet Type I (Page 1 of 2)
SD‐21.2 Corrugated Metal Pipe Drainage Inlet Type I (Page 2 of 2)
SD‐22 Corrugated Pipe Fittings
SD‐23 Pipe Connects
SD‐24 Flexible Pipe to Manhole Connection
SD‐25 Typical Ramp and Transition Detail
SD‐26 Outlet Pipe Headwall and Apron
SD‐27 Ditch Discharge Control and Apron
SD‐28.1 Trash Rack 24”‐36” Pipe (Sheet 1 of 4)
SD‐28.2 Trash Rack 42” Pipe and Larger (Sheet 2 of 4)
SD‐28.3 Trash Rack 42” Pipe and Larger (Sheet 3 of 4)
SD‐28.4 Trash Rack Details (Sheet 4 of 4)
SD‐29.1 Inlet Pipe Headwall Wingwall Structure (Sheet 1 of 2)
SD‐29.2 Inlet Pipe Headwall Wingwall Structure (Sheet 2 of 2)
SD‐30.1 Lined Channel Section (Sheet 1 of 2)
SD‐30.2 Lined Channel Section (Sheet 2 of 2)
SD‐31 Utility Stream Crossing

Back to top


Street Lighting

Section Name Name
SL‐1 Street Lighting Poles and Symbols
SL‐2 Street Lighting Illumination Criteria
SL‐3 Street Light Foundations
SL‐4 Standard Pull Box
SL‐5 Traffic‐Rated Pull Box
SL‐6 Base Location for Street Light
SL‐7 Underground Service Installation
SL‐8 Metered Service Pedestal (Can) (120/208V, 120/240V)
SL‐9 Metered Service Pedestal (Can) with Step‐Down Transformer (277/480V to 120/240V)
SL‐10 Unmetered Service Pedestal (Can) (120/208v, 120/240V, 277/480V)
SL‐11 Unmetered Service Enclosure (Can) with Step‐Down Transformer (277/480V to 20/240V)
SL‐12 In‐Line Fuse Requirements
SL‐13 2‐Wire Street Light System Wire Size and Voltage Drop Calculation
SL‐14 3‐Wire Street Light System Wire Size and Voltage Drop Calculation
SL‐15 Conduit, Service Wire and Breaker Sizing
SL‐19 Street Light Areas
SL‐20 Common Type Electrolier (Series 'A')
SL‐22 Common Type Electrolier (Series 'B')
SL‐24 Common Type Street Light Pole Spacing Guide (Series 'A'/Series 'B')
SL‐25 Common Type Typical Locations Arterial Streets (Series 'A'/Series 'B')
SL‐26 Common Type Typical Locations Collector and Residential Streets (Series 'A'/Series 'B')
SL‐30 Zone 2 Electrolier (Dual Arm)
SL‐31 Zone 2 Electrolier (Series 'A')
SL‐33 Zone 2 Luminaire Options (Series 'A')
SL‐34 Zone 2 Electrolier (Series 'B')
SL‐36 Zone 2 Pole Spacing Guide (Series 'A'/Series 'B'/Dual Arm)
SL‐37 Zone 2 Typical Locations Arterials and Collectors with Medians (Series 'A'/Series ‘B’/Dual Arm)
SL‐38 Zone 2 Typical Locations Collector and Residential Street (Series 'A'/Series 'B')
SL‐40 Laguna West Electrolier (Dual Arm)
SL‐42 Laguna West Electrolier (Dual Arm)
SL‐46 Laguna West Electrolier (Dual Arm)

Back to top


Stormwater Quality

Section Name Name
SQ‐1 Stabilized Construction Site Access
SQ‐3 Sediment Trap Stabilized Outlet SQ‐3
SQ‐4 Fiber Rolls
SQ‐5 Silt Fence
SQ‐6 Concrete Washout
SQ‐7 Inlet Sediment Control
SQ‐8 Storm Drain Inlet Filter Bag
SQ‐9A Erosion Control Blankets/Mats Channel Installation
SQ‐9B Erosion Control Blankets/Mats Slope Installation
SQ‐10.1 Drop Inlet Concrete Stamp (Sheet 1 of 2)
SQ‐10.2 Drop Inlet Concrete Stamp (Sheet 2 of 2)

Back to top


Streets

Section Name Name
ST‐1A Trench Backfilling and Resurfacing
ST‐5 Trench Resurfacing When Fabric is Required
ST‐6A Utility Pothole Repair
ST‐7 General Notes
ST‐8A Manhole Backfill Detail
ST‐8 Typical Trench Compaction Detail
ST‐9 Temporary Trench Resurfacing
ST‐10 Trench Sections in Improved Area Horticulture, Lawn or Cultivated Areas
ST‐11 Widening Details for Thoroughfares at Various Street Intersections
ST‐12A Widening Details for Arterials at Major Street Intersections
ST‐12B Widening Details for Arterials at Collector Street Intersections
ST‐13 Typical Striping for Collector Streets with Bicycle Lanes at Intersections with Thoroughfare or Arterial Streets
ST‐14A Typical Striping for Arterial Intersections with Thoroughfares or Arterials
ST‐14B Typical Striping for Arterial Intersections with Collectors
ST‐15A Typical Striping for Thoroughfare Intersections with Thoroughfares or Arterials
ST‐15B Typical Striping for Thoroughfare Intersections with Collectors
ST‐16 Typical Raised Island Designs for Limiting Access
ST‐17A Typical Sections Interim Improvements for Special Thoroughfare and Thoroughfare Streets with Rolled‐In Rumble Strips
ST‐17B Rolled‐In Rumble Strips for Interim Roadway Improvements
ST‐17C Rolled‐In Rumble Strips for Interim Roadway Improvements
ST‐17D Typical Sections Interim Improvements for Special Thoroughfare and Thoroughfare Streets with Rolled‐In Rumble Strips
ST‐17 Typical Sections Streets Classes "A", "B", and "C"
ST‐18 Class "C" Street Intersection
ST‐19 Typical Street Sections at Residential Driveways
ST‐20 Commercial Driveways Type A‐6
ST‐21B Sidewalk Ramp for A‐7 Driveways Without Additional R/W (Not for New Construction)
ST‐22 Driveway Location Standards
ST‐23 Cul‐De‐Sac
ST‐24 Bulb‐Out Detail
ST‐25 90 Degree Intersection Elbow
ST‐26.1 Minimum Sight Distance at Intersections and Non‐Residential Driveways
ST‐26 Visibility Requirements, City of Elk Grove
ST‐27 Bus Turnouts
ST‐28 Bus Stop Details
ST‐30 A.C. Conforms to New Sidewalk Ramp Re‐Construction
ST‐31 A.C. Conforms to New Sidewalk Ramp Re‐Construction
ST‐33 Barrier Curb Detail
ST‐34 Under Sidewalk
ST‐35 Separated (Or Detached) Sidewalk Transition
ST‐36 A.C. Sidewalk Conform
ST‐37 Residential Corner Lot Driveway Location Residential or Collector Streets
ST‐38 Pavement Widening Detail
ST‐39 Standard Concrete Joint Details
ST‐40 Street Survey Monument
ST‐41 Street Closure Timber Barricade
ST‐42 Signs and Barricades at Abrupt Change of Pavement Width
ST‐43 Sidewalk Barricade
ST‐44 Multi‐Use Trail Connections at Driveways and Intersections

Back to top


Traffic

Section Name Name
T‐1 Stop Sign and Stop Legend Location
T‐2A Bollard Detail
T‐2B Asphalt Speed Hump Detail (W=26' – 34')
T‐2C Asphalt Speed Hump Detail (1) (W=26' – 34')
T‐2D Asphalt Speed Hump Detail (2) (W=36' – 44')
T‐2E Asphalt Speed Table Detail (W=26' – 44')
T‐2 Pre‐formed Rubberized Speed Cushion Layout and Typical Signing and Striping (42', 36', 26' Paved Roadway)
T‐3 Street Name Sign
T‐4 Private Street Name Sign
T‐5A Street Name Sign on Street Light Pole Placement Detail
T‐5B Street Name Sign on Electroliers
T‐6A Street Name Sign General Location
T‐6B Street Sign Location
T‐7 Bike Loop and Bike Legend Installation Detail
T‐8 Mid‐Block Crosswalk at Uncontrolled Locations
T‐9A Typical Street Cross Locations
T‐9B Typical Street Cross Sections 72', 96', and 118'
T‐9C Typical Street Cross Sections Frontage Road
T‐9D 20‐Foot Street (Private Alley)
T‐10 Class C Street Cross Section
T‐11 Pedestrian Lane with Bike Barrier
T‐12 Concrete Foundation for Type P Controller Cabinet and Type III Service Cabinet
T‐13 (Edge‐Lit LED) Internally Illuminated Street Name Sign
T‐14 IISNS Support Arm Typical Clamp Detail
T‐15 Conduit, Service Wire and Breaker Sizing
T‐16 Typical Detector Loop Layouts
T‐17 Type "B" Detector Handhole Detail
T‐18 Interconnect Terminal Cabinet and Pedestrian Signal Controller Cabinet Details
T‐19 Accessible Pedestrian Signal System
T‐20 CCTV IP Dome Camera (Signal Pole Mounted)

Back to top

© 2021 City of Elk Grove. All Rights Reserved.